Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Forensic Sci Int Genet ; 14: 174-81, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25450789

RESUMO

The genotypes of 36 Y-chromosomal short tandem repeat (Y-STR) marker units were analysed in a Dutch population sample of 2085 males. Profiling results were compared for several partially overlapping kits, i.e. PowerPlex Y, Yfiler, PowerPlex Y23, and two in-house designed multiplexes with rapidly mutating Y-STRs. Nineteen Y-STR marker units, of which two are rapidly mutating, reside in at least two of these multiplexes, and for these markers concordance testing was performed. Two samples showed discordant genotyping results and the probable causative base change was revealed by Sanger sequencing. In addition, we encountered concordant, but aberrant genotyping results including one allele with low peak height and several null alleles. For 12 samples, this involved a null allele in two adjacent loci suggesting a large and recurrent deletion as the samples represent three distinct haplogroups. For each marker unit, the allele counts and frequencies are presented, as are the haplotype counts and haplotype diversities for several combinations of markers.


Assuntos
Cromossomos Humanos Y , Marcadores Genéticos , Repetições de Microssatélites/genética , Eletroforese Capilar , Humanos , Masculino , Países Baixos , Linhagem , Reação em Cadeia da Polimerase
2.
Forensic Sci Int Genet ; 10: 55-63, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24680126

RESUMO

Regularly, STR results obtained with different PCR amplification kits are compared, for instance with old cases, when revisiting cold cases or when addressing cross-border crimes. It is known that differences in primer design for the same loci in different kits may give rise to null alleles or shifted alleles. In this study, the genotyping results of 2085 Dutch male samples were compared for six autosomal STR kits (Promega's PowerPlex(®) 16, ESX-16 and ESI-17 Systems, Qiagen's Investigator(®) ESSplex Kit and Applied Biosystems' AmpFlSTR(®) Identifiler and NGM PCR Amplification Kits). A total of 19 discordant autosomal genotyping results were obtained that were examined by sequence analysis using Roche-454 next generation sequencing and/or Sanger sequencing. A further 25 discordances were found and sequenced for the Amelogenin locus. The 24 samples showing the same primer binding site mutation at the Amelogenin locus were subjected to X-STR analysis in order to assess whether they could share a common origin, which appeared not to be the case. Based on the sequencing results, we set the final genotypes and determined the allele frequencies of 23 autosomal STRs for the Dutch reference database.


Assuntos
Genética Populacional , Repetições de Microssatélites , Frequência do Gene , Humanos , Países Baixos , Reação em Cadeia da Polimerase
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...